JYWQ sewage pump

JYWQ series automatic mixing sewage pump adopts automatic mixing device on the basis of ordinary sewage pump. The device rotates with the motor shaft to produce extremely strong stirring force, stirring the sediment in the sewage tank into suspended matter, and sucking in The discharge inside the pump improves the anti-blocking and sewage discharge ability of the pump, completes drainage, cleaning, and desilting at one time, saving operating costs, and is an environmentally friendly product with obvious advancement and usability. 

Main features
1. When the automatic stirring sewage pump is running, it will automatically stir the sediment at the bottom of the pool to completely prevent the accumulation of dirt without manual cleaning;

2. The unique impeller design has the function of shredding and tearing fibers and sundries;

3. Adopt the external circulation cooling system to make the sewage pump run at low water level, reduce the starting frequency of the motor and extend the life of the motor

4. Recommended products in the National Standard Atlas;

5. High-tech achievement transformation products.

JYWQ sewage pump model meaning
Example: 80JYWQ50-10-1600-3

80-discharge outlet diameter (mm)

JYWQ-automatic mixing sewage pump

50-flow (m3/h) 10-head (m) 1600-mixing range (mm) 3-motor power (KW)

The main purpose
1. Discharge of wastewater from factories and businesses seriously polluted.

2. Drainage systems of urban sewage treatment plants, hospitals, and hotels.

3. Sewage drainage station in residential area.

4. The water supply device of the drainage station of the civil air defense system and the water supply plant.

5. Municipal engineering, construction site.

6. Attached equipment for exploration, mining, and power plants.

7. Rural biogas digesters, farmland irrigation, and river pond dredging.

JYWQ sewage pump structure diagram
Description of structural features

1622701803871702.

1. The unique double-flow channel non-blocking impeller structure is adopted to improve the flow capacity and sewage discharge capacity of sewage.

2. The automatic stirring device produces extremely strong stirring power. The sediment in the pool is stirred into a suspended matter and then sucked into the impeller to discharge it to achieve the effect of dredging.

3. The partition divides the base into two, and mixing and water inflow do not affect each other.

4. The mechanical seal is a double-end mechanical seal, which is kept in the oil chamber for a long time to ensure the safe and reliable operation of the water pump.

5. The hydrodynamic seal of the auxiliary impeller structure not only has the auxiliary sealing function, so as to protect the mechanical seal, but also balance the axial force and prolong the service life of the bearing.

6. There is no water leakage detection probe in the connection cavity of the pump. When there is water leakage, the probe sends out a signal, and the control system protects the pump. The company can be equipped with a fully automatic safety protection control cabinet.

7. The motor stator adopts Class B and Class F insulation, and a thermal protector is built in. When the motor is overloaded and heats up, the protector will act in time to provide absolute protection to the pump and motor.

8. An oil-water probe is installed in the oil chamber. When the mechanical seal is damaged, water enters the oil chamber, and the probe sends a signal to protect the water pump by the control system.

9. JPWQ has an internal circulating cooling system to ensure that the water pump works normally at the low water level of the pool.

1 Main cable  2 case 3 Inner loop sleeve 4 oil box 5 expeller 6 impeller 7 Frame plate
8 Base 9 clapboard 10 Oil-water control head 11 Machinery Seal 12.bearing 13 agitator parts  

Performance parameter table
  model discharge max max agitator speed eff. automatic
diameter flow head diameter      
(mm) (m3/h) (m) (mm) (r/min) (%) coupler
1 JYWQ50-12-15-1200-1.5 50 12 15 1200 2900 48 CAK-50
2 JYWQ50-20-7-1200-1.1 50 20 7 1200 2900 62 CAK-50
3 JYWQ50-10-10-1200-1.1 50 10 10 1200 2900 56 CAK-50
4 JYWQ50-15-15-1200-2.2 50 15 15 1200 2900 51 CAK-50
5 JYWQ50-25-10-1200-2.2 50 25 10 1200 2900 65 CAK-50
6 JYWQ50-15-20-1200-2.2 50 15 20 1200 2900 56 CAK-50
7 JYWQ50-20-15-1200-2.2 50 20 15 1200 2900 56 CAK-50
8 JYWQ50-42-9-1200-3 50 42 9 1200 2900 56 CAK-50
9 JYWQ50-17-25-1200-3 50 17 25 1200 2900 56 CAK-50
10 JYWQ50-25-22-1200-4 50 25 22 1200 2900 62 CAK-50
11 JYWQ50-40-15-1400-4 50 40 15 1400 2900 70 CAK-50
12 JYWQ50-25-32-1600-5.5 50 25 32 1600 2900 52 CAK-50
13 JYWQ50-40-30-1600-7.5 50 40 30 1600 2900 68 CAK-50
14 JYWQ65-25-15-1400-3 65 25 15 1400 2900 65 CAK-65
15 JYWQ65-37-13-1400-3 65 37 13 1400 2900 62 CAK-65
16 JYWQ65-25-28-1400-4 65 25 28 1400 2900 60 CAK-65
17 JYWQ80-40-7-1600-2.2 80 40 7 1600 2900 54 CAK-80
18 JYWQ80-29-8-1600-2.2 80 29 8 1600 2900 54 CAK-80
19 JYWQ80-43-13-1600-4 80 43 13 1600 2900 63 CAK-80
20 JYWQ80-50-10-1600-3 80 50 10 1600 1450 76 CAK-80
21 JYWQ80-40-15-1600-4 80 40 15 1600 2900 70 CAK-80
22 JYWQ80-60-13-1600-4 80 60 13 1600 2900 70 CAK-80
23 JYWQ80-35-25-1600-5.5 80 35 25 1600 2900 64 CAK-80
24 JYWQ80-50-25-1600-7.5 80 50 25 1600 2900 70 CAK-80
25 JYWQ80-50-30-1600-7.5 80 50 30 1600 2900 70 CAK-80
26 JYWQ100-80-9-2000-4 100 80 9 2000 1450 62 CAK-100
27 JYWQ100-110-10-2000-5.5 100 110 10 2000 1450 71 CAK-100
28 JYWQ100-70-15-2000-5.5 100 70 15 2000 1450 71 CAK-100
29 JYWQ100-100-15-2000-7.5 100 100 15 2000 1450 73 CAK-100
30 JYWQ100-80-20-2000-7.5 100 70 20 2000 2900 71 CAK-100
31 JYWQ100-50-35-2000-11 100 100 35 2000 2900 68 CAK-100
32 JYWQ100-70-22-2000-7.5 100 80 22 2000 2900 70 CAK-100
33 JYWQ100-100-22-2000-15 100 150 22 2000 1450 61 CAK-100
34 JYWQ100-80-30-2000-15 100 210 30 2000 1450 67 CAK-100
35 JYWQ150-150-10-2000-7.5 150 250 10 2000 1450 75 CAK-150
36 JYWQ150-210-7-2500-7.5 150 150 7 2500 1450 78 CAK-150
37 JYWQ150-250-6-2500-7.5 150 200 6 2500 1450 79 CAK-150
38 JYWQ150-150-15-2500-11 150 65 15 2500 1450 79 CAK-150
39 JYWQ150-200-10-2500-15 150 180 10 2500 1450 73 CAK-150
40 JYWQ150-65-40-3200-18.5 150 150 40 3200 1450 58 CAK-150
41 JYWQ150-180-22-2600-18.5 150 110 22 2600 1450 75 CAK-150
42 JYWQ150-150-26-2600-18.5 150 300 26 2600 1450 72 CAK-150
43 JYWQ150-110-30-2600-18.5 150 130 30 2600 1450 72 CAK-150
44 JYWQ150-300-15-2600-22 150 100 15 2600 1450 76 CAK-150
45 JYWQ150-130-30-2600-22 150 300 30 2600 1450 70 CAK-150
46 JYWQ150-100-40-3000-30 150 250 40 3000 1450 64 CAK-150
47 JYWQ200-300-7-3000-11 200 300 7 3000 1450 75 CAK-200
48 JYWQ200-250-11-3000-15 200 250 11 3000 1450 72 CAK-200
49 JYWQ200-300-10-3000-15 200 300 10 3000 1450 75 CAK-200
50 JYWQ200-250-15-3000-18.5 200 250 15 3000 1450 72 CAK-200
51 JYWQ200-400-10-3000-22 200 400 10 3000 1450 75 CAK-200
52 JYWQ200-200-20-3000-22 200 200 20 3000 1450 73 CAK-200
53 JYWQ200-250-22-3000-30 200 250 22 3000 1450 73 CAK-200
54 JYWQ250-600-7-3000-22 250 600 7 3000 1450 78 CAK-250
55 JYWQ250-600-9-3000-30 250 600 9 3000 1450 78 CAK-250
 
Precautions
(1) Use a megohmmeter to check the insulation resistance of the stator winding of the motor to the ground before operation, and the value shall not be less than 50 megohm

(2) Check whether the cable is damaged or broken. If it is damaged, it must be replaced in time to avoid leakage; the cable section should match the current.

(3) When the voltage exceeds ±10% of the rated voltage, the electric pump shall not be started.

(4) To ensure safe use, the grounding wire in the four-core cable must be reliably grounded to prevent electric shock accidents.

(5) When the electric pump is submerged in the water, it should be lifted vertically, and it is not allowed to lay on the ground horizontally, let alone sink into the sludge. When stopping use, the electric pump should be lifted and cleaned, placed in a dry place, and take care to prevent freezing.

(6) It is forbidden to use the cable as a lifting rope for installation.

(7) Check the running direction of the rotor, it should rotate clockwise from top to bottom.

(8) Outdoor switches or terminals should be protected from rain and moisture. It is forbidden to touch the switch with wet hands or barefoot to prevent electric shock.

(9) When moving the electric pump, the power supply must be cut off, and people must not touch the water source when the electric pump is running to prevent personal accidents from leakage.

(10) It is strictly forbidden to run the motor under phase loss. If the fuse is found to be blown, you should check the cause before continuing to use it. The fuse should not be thickened arbitrarily.

(11) When the pump is running, it should be managed by a special person. If any abnormality is found, it should be shut down immediately for inspection and troubleshooting. (Refer to the case of fully automatic protection cabinets).

(12) After the electric pump has been in normal operation for half a year under the specified working medium conditions, check the sealing condition of the oil chamber. If the oil in the oil chamber is milky or has water precipitation, replace the No. 10-20 mechanical oil and mechanical seal in time. For electric pumps used under severe working conditions, they should be overhauled frequently.

(13) The user should select the appropriate flow head according to the actual operating conditions to achieve the best use effect. The parameters shown on the pump nameplate or manual are the best operating conditions, and the user can choose (0.7~1.2) times better Use within the flow, prohibit the use of excessive flow, otherwise the flow is too large, and the head is too low, which will easily overload the motor.